Water Supply Nipple Mamelon Nipple
� Pressure Balancing Loop 1. Route the water supply lines.
2. If installing more than one bodyspray off the same supply line, construct a pressure balancing loop. Locate a tee along the loop at each bodyspray installation location.
3. Do not strap the pipes at this time.
Single Bodyspray Installation
� Nipple Mamelon Nipple
1. Route the water supply line.
2. Install an elbow to the end of the supply pipe at the bodyspray installation location.
|
Install the Plaster Guard
� Elbow (or Tee)
� Install the plaster guard
Set Piping Depth
Align mark with the front of the stud face
� Thin Wall
Align mark with the front of the stud face
� Standard Wall
Install the plaster guard. Push until the plaster guard is snug against the face of the elbow (or tee).
|
|
1. Install the water-resistant wallboard.
2. Cut out a 4" (10.2 cm) to 4-1/4" (10.8 cm) square at each of the installation location.
3. Install the finished wall material
|
1. Insert the escutcheon into the rough opening. The double ribs of the leak shield should be facing up.
2. If the leak shield makes contact with the elbow: Enlarge the hole in the back of the leak shield to 1-1/4" (3.2 cm).
3. Thread the adapter onto the nipple using the provided 11 mm bit, 11 mm or 7/16" socket, extension and socket wrench. Use masking tape to hold the bit in place, as the bit could fall off and cause damage.
IMPORTANT! The escutcheon should sit loosely at this point. If it is tight against the wall, use a longer pipe nipple.
4. Align the groove in the waterway with the double ribs on the leak shield.
5. Press the waterway into place over the adapter. Secure the waterway to the adapter with the screw provided.
6. Verify that the escutcheon does not turn or shift. � Escutcheon � Leak Shield � Adapter � Extension � Socket Wrench With Bit � Screw � Waterway Passage
|
|